Fire Door Blanks
Our fire door blanks provide a strong, adaptable base for standard, oversized and non-standard door openings. Available in two practical sizes, these 44mm plywood-faced fire door blanks are designed for suitable FD30 door assemblies. They allow accurate sizing and finishing across internal installations and correctly treated external applications.
44mm Plywood-Faced FD30 Fire Door Blank 2135mm x 915mm (7' x 3')-£6.58£98.77 £82.31 £105.35
44mm Plywood-Faced FD30 Fire Door Blank 2440mm x 1220mm (8' x 4')-£24.46£150.00 £125.00 £174.46
Fire Door Blank FAQs
What is a fire door blank?
A fire door blank is an unfinished, adaptable panel designed to be processed into a fire door leaf. It is not a complete fire door or doorset on its own. Its stated fire performance depends on the finished leaf being manufactured and installed within the relevant fire-test evidence, using compatible lippings, frames, seals, glazing and ironmongery.
What does FD30 mean on a fire door blank?
FD30 indicates a doorset construction designed to provide at least 30 minutes of fire integrity when manufactured and installed in its tested configuration. For the Therman 44 system, the manufacturer reports full-door assembly testing in UKAS-accredited laboratories to BS EN 1634-1 and BS 476-22. FD30 alone should not be treated as confirmation of smoke-control performance where smoke resistance is also required.
What sizes are fire door blanks available in?
The current MGN range includes 2135 × 915 × 44mm (7' x 3') and 2440 × 1220 × 44mm (8' x 4') fire door blanks. Choose a blank large enough to cover the required finished leaf dimensions while allowing for permitted trimming, lipping and machining. Always verify the proposed finished size against the manufacturer's current fire-test evidence.
Can an FD30 fire door blank be cut to size?
Yes, but only within the manufacturer's permitted processing limits. Therman 44 fire door blanks have no perimeter framing within the core, allowing them to be cut to the required leaf size for lipping. The final leaf dimensions, trimming, lippings, hardware machining and any apertures must remain within the relevant fire-test or certification evidence.
Do fire door blanks need lipping?
The fire door blanks in this category are supplied unlipped, but the required finished edge construction depends on the relevant fire-test evidence. Therman documentation supports specified engineered and natural timber lippings as well as tested arrissed-edge details. Do not assume that any standard hardwood lipping, adhesive or dimensions will be suitable.
Who should process and install a fire door blank?
Cutting, lipping, glazing and hardware machining should be completed by a competent fire-door processor working within the manufacturer's current test or certification evidence. Where third-party certification must be retained, use a processor licensed for the relevant blank and certification scheme. The finished doorset should also be installed by a trained and competent fire-door installer following product-specific instructions.
Can fire door blanks be used externally?
The manufacturer states that the Therman 44 fire door blanks in this category are suitable for both internal and external use. External suitability does not mean that an unfinished blank can be left exposed to the weather. Confirm that the complete doorset specification, including its facings, lippings, frame, components and protective finish, is approved for the intended location and exposure.